Tornado Protection
Citadel Storefront solutions with tornado protection secures your structure in the face of an F-5 tornado—at half the price of other tornado protection systems.
It features the only high-impact door in the industry that has passed both tornado and 15-lb water intrusion testing with full handicap accessibility. Each door panel incorporates a full-length piece of glass to maintain the traditional storefront look.
Our tornado protection design:
- Withstands storm-generated vacuum—in testing it held negative 300 psf (nearly 7 tons) for 10 seconds
- Withstands storm debris—in testing it survived four impacts by a 15-lb 2x4 projectile traveling 100 mph fired at the weakest point of the frame.

Pinellas County Emergency Responders Building, Tampa

Features
- Only glazed storefront successfully tested to FEMA 361 guidelines
- Only door to pass all Dade County hurricane requirements (including the 21 psf water resistance test) using a 1/2-in handicap accessible threshold
- Only door secured using CDI’s proprietary locking mechanism that can withstand high loads of forced entry attempts
- Windows and doors made with aluminum frames; available in a variety of finishes
- Window dimensions can be either horizontal or vertical
- Each door leaf is provided with a G-86/4781 paddle panic exit device
- Doors are compatible with electronic activation devices
Testing and Certifications
Design tested per FEMA 361 guidelines:
- Static negative pressure: 300 psf for 10 seconds
- Impacts with 15-lb 2x4 at 100 mph (2 for window, 4 for door system)
Design fully certified to the following standards:
- Large Missile Impact Test per FBC, TAS 201-94 (ASTM E1886)
- Cyclic Wind Pressure Loading per FBC, TAS 203-94 (ASTM E1996)
- Air Infiltration Test, per FBC, TAS 202-94 (ASTM E283-91)
- Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 (ASTM E330-97)
- Water Resistance Test, per FBC, TAS 202-94 (ASTM E331-00)
- Forced Entry Test, per FBC 3693.2 (b) and TAS 202-94