Tornado Protection

Citadel Storefront solutions with tornado protection secures your structure in the face of an F-5 tornado—at half the price of other tornado protection systems.

 It features the only high-impact door in the industry that has passed both tornado and 15-lb water intrusion testing with full handicap accessibility. Each door panel incorporates a full-length piece of glass to maintain the traditional storefront look.

Our tornado protection design: 

  • Withstands storm-generated vacuum—in testing it held negative 300 psf (nearly 7 tons) for 10 seconds
  • Withstands storm debris—in testing it survived four impacts by a 15-lb 2x4 projectile traveling 100 mph fired at the weakest point of the frame.

Pinellas County Emergency Responders Building, Tampa

Features

  • Only glazed storefront successfully tested to FEMA 361 guidelines
  • Only door to pass all Dade County hurricane requirements (including the 21 psf water resistance test) using a 1/2-in handicap accessible threshold
  • Only door secured using CDI’s proprietary locking mechanism that can withstand high loads of forced entry attempts
  • Windows and doors made with aluminum frames; available in a variety of  finishes
  • Window dimensions can be either horizontal or vertical
  • Each door leaf is provided with a G-86/4781 paddle panic exit device
  • Doors are compatible with electronic activation devices

Testing and Certifications

 Design tested per FEMA 361 guidelines:

  •  Static negative pressure: 300 psf for 10 seconds
  • Impacts with 15-lb 2x4 at 100 mph (2 for window, 4 for door system)

Design fully certified to the following standards:

  •  Large Missile Impact Test per FBC, TAS 201-94 (ASTM E1886)
  • Cyclic Wind Pressure Loading per FBC, TAS 203-94 (ASTM E1996)
  • Air Infiltration Test, per FBC, TAS 202-94 (ASTM E283-91)
  • Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 (ASTM E330-97)
  • Water Resistance Test, per FBC, TAS 202-94 (ASTM E331-00)
  • Forced Entry Test, per FBC 3693.2 (b) and TAS 202-94